For proper air sampling duct pressure should be a minimum of 0 01 inches of water.
Duct smoke detector installation location.
Because carbon monoxide is slightly lighter than air and also because it may be found with warm rising air detectors should be placed on a wall about 5 feet above the floor.
5 2 determine mounting location and configuration on ducts wider than 18 inches it is recommended that the detector be mounted downstream of a bend obstruction in the duct or the supply or return air inlet.
Nfpa 90a is specific to air conditioning and heating systems installation.
Install smoke alarms inside each bedroom outside each sleeping area and on every level of the home including the basement.
In the areas where smoke detectors become inaccessible designers should include smoke detection controls remote from the inaccessible area.
2 6 p n 3101210 rev 02 iss 28jan13.
The detector may be placed on the ceiling.
To ensure correct operation install the duct detector using the following guidelines.
Do not place the detector right next to or over a fireplace or flame producing appliance.
We will show you how to wire a system sensor duct smoke detector to a carrier bryant or icp furnace and then configure it s communicating infinity evoluti.
Prior to the installation of the damper and smoke detector.
Duct detectors smoke detection nfpa 90a code requirements this article references the current nfpa 90a standard for the installation of air conditioning and ventilating systems.
Installation of duct detectors can.
Standard location when factory mounted will be on the side opposite the damper actuator.
At these locations air flow is less turbulent and the air smoke mixture should be more homogenous refer to nfpa 90a 72 and 101 for more information.
It provides basic instruction on the installation of smoke detectors inside the ductwork.
Duct smoke detectors should be located in the hvac area between 6 and 10 duct equivalent diameters of straight uninterrupted run.
D4120 duct smoke detector d4s sensor component.
If the detector is.
Install the duct smoke detector on a flat section of hvac duct between six and ten duct widths from any bends or obstructions.
Due to smoke dilution in the ducts the duct detectors will respond more slowly than an area detector.
On levels without bedrooms install alarms in the living room or den or family room or near the stairway to the upper level or in both locations.
To check the air velocity in the duct.
The inlet sampling tube is to be located between blades to avoid blockage of the airflow past the tube.