You need to make a transition from nm cable s to exterior pvc conduit.
Electrical conduit through exterior wall.
Drill a hole in the wall.
I advise an interior surface mounted metallic outlet box with a thru the wall pvc conduit nipple between the interior outlet box and an exterior pvc lb fitting the lb is used for making a horizontal to vertical change in the direction of the pvc with the body of the lb in line with the exterior pvc.
You will need to choose the right size of the drill bit.
There are two ways to run electrical wiring on the exterior walls of a house or other structure.
Running the conduit through the wall to an inside box is the most difficult step.
Use screws and faster the box to the looks like wood so use some longer wood screws about 6 and fasten it tightly to the wall.
The first thing that you will need to do is to drill a hole in the wall.
Use outdoor silicone caulking around the conduit at the structure in order to hold the conduit into place and keep water from going inside your structure.
Below we have provided a step by step guide to help you to install a conduit through your exterior wall.
How to run conduit through exterior wall step 1.
The material used to make a rigid conduit can be connected with watertight removable fittings or glued together using pvc cement.
It is also used in unfinished areas like basements crawlspaces and attics and for surface mounted installations outdoors.
Some sand paper make it kinda rough.
Solid wall rigid pvc conduit is suited for any application which requires conduit for electrical or plumbing chases.
One method is to run individual wires in a conduit system such as intermediate conduit rigid.
You ll start by bending the first pipe and threading an lb onto the end.
A favorite target of electrical inspectors is the improper use of non metallic cable nm in exposed locations such as basement foundation walls or along the face of studs and joists in unfinished framed spaces.
Use water resistant silicone and apply around the pipe area and on the edges of the square.
The national electrical code which is the basis for all local building codes has specific regulations for installing electrical wires so that they are protected from damage.
Slide a short piece of schedule 40 pvc conduit through the structure s wall so that you can attach an lb fitting onto it.
The best way is to clean the area behind the box on the outside wall.
The 10 foot lengths of rmc are threaded on both ends and include a coupling on one end.
The size of conduit that is needed will be depend on the number and size of the electrical wires being run through it based on tables c9 and c10 of the national electrical code.